婷婷爱爱 I 亚洲中文无码av永久 I a级毛片在线免费 I 日韩avav I 78m78成人免费网站 I 亚洲国产成人精品av区按摩 I 日本黄色a v I 91n.com在线观看 I 99久精品视频 I 歪歪爽蜜臀av久久精品人人 I 国产精品少妇在线视频 I 亚洲欧美日韩中文字幕在线一区 I 欧美精品1区2区 I 操日本美女b I 91精品国产99久久久久 I 国产在线无码视频一区二区三区 I 999久久久免费精品播放 I 天天插综合网 I 亚州视频在线 I 性开放网站 I 午夜在线视频 I 欧美性导航 I 九九热最新地址 I 伊人婷婷久久 I 成人精品中文字幕 I 人妻少妇精品久久久久久 I 中文字幕日日骚 I 欧洲激情一区二区 I 精品亚洲一区二区三区四区 I 很色很爽很黄裸乳视频 I 免费a黄色 I 亚洲欧美文学 I 国产尻逼视频 I 欧美日韩中国免费专区在线看 I 五月天久久网站

  • 1
  • 2

Products

Contact Us

Hotline::400-820-8239
Meijun Metals (Shanghai) Co., Ltd. 
Tel:021-68183992 
Fax:021-68183990

Details
Position: Home> Details

ACP5080RS

ACP5080RS
  • 產(chǎn)品介紹

ACP 5080(R)S

for Vacuum Chamber Applications

On the base of EN AW 5083 aluminum cast alloy, alimex developed a top quality cast material for

the most challenging and critical applications of innovative, high-end industries like the

Electronics, Semiconductor, Solar and Display Panel industry.

Through decades of practical application experience, continuous material research, development

and testing, ACP 5080(R)S provide good mechanical and physical properties as compared with

similar competitors’ cast and rolled aluminum plates.

Material excellence and superiority is achieved through the proprietary smelting, manufacturing,

processing and handling procedures and specifications employed in the production of this grade.

2

ACP 5080(R)S

for Vacuum Chamber Applications

Special features

? Especially homogenized

? Stress relieved

? Ultrasonic tested

? Reduced micro-porosity

? Tested by:

? Fraunhofer Institut für Chemische Technologie

? Forschungszentrum Julich (Outgasing test and Helium leak test)

3

ACP 5080(R)S

Outgassing Test

Description of the test:

Residual gas and outgassing measurements were performed on 3 casted aluminum plates (ACP 5080S).

Before measurements were made, the specimens were subjected to a cleaning procedure according

to FZJ-COSY specifications (10 min ultrasonic cleaning at 60 °C in hydrocarbon-free, alkaline

washing solution pH 8.5 – 9.0).

The investigations were performed on two specimen at room temperature, and for one specimen

the temperature was increased to 160 °C for 12 h during the measuring process. The curve of the

partial pressure against time was recorded for selected atomic masses (AMU). At the

beginning and end of these trend measurements, analogue measurements were

recorded for the entire measuring range (AMU 1 –200).

For measurement results please take a look at the attached Outgassing Test.

4

ACP 5080(R)S

Helium Leak Test

Description of the test:

On 5 plates casted from aluminum (ACP 5080S), long-term measurements of the helium-permeability,

according to the local vacuum method (DIN EN 1779 – A3), were carried out. A possible He-leakage

should be measured for 24 hours testing time.

Subsequently all testing parts are connected separately to the intake flange of the leak-detectorand

sealed with aluminum gaskets ?Ultra-Dichtring“ from LEYBOLD (see draft, schematic test assembly,

attachment 1, fig 1 u. 2). From the inner diameter of the sealing ring a measuring area of A = 822

mm2 x π/4 = 5278 mm2 is calculated. All objects were cleaned with alcohol before

testing. The measurements were carried out at a differential test pressure of

?p = 1 bar and room temperature (~25°C).

For measurement results please take a look at the attached Helium Leak Test.